Loading...
01 1st flr (15)-0© Streibert Associates - Architects Scale: 1/4" = 1' - 0" STREIBERT ASSOCIATES 15 Linden Tree Lane Chatham, Massachusetts 02633 Architects 508-945-1459 8 May 2022 2201Seashore Homes, Inc. 63 East Main Street Hyannis, MA 02601 1st Floor Plan A1N4'-0"8'-6"WD27 6'-10 3/4"12'-8 5/8"12'-8 5/8"Bedroom Bath Living / Dining moved Bedroom Living / Dining 8 1/4"R, 9"T upStorage 2 3/4" linen pantry 34'-0 1/2"3'-0"24 WD27 Bath linen pantry 60 24WD27Bedroom Bath Living / Dining upStorage8 1/4"R, 9"T D7 linenpantry 3'-0"6024Bedroom Living / Dining WD27 Bath linen pantry3'-0"60 24 5 1/2"28'-0"up608'-11 1/4"Office 19'-0" Bilco C Bulkhead 4'-7" x 6'-0" doors Bath 4'-0 3/4" HVAC HVAC HVAC HVACHVACHVACHVACHVAC HVAC 1st Floor Hall 60 30 30 9'-3"4'-6"5'-0"4'-6"4 1/2" 3'-0"8'-6"4'-0" 30 30 Pole and Shelf Pole and Shelf Pole and Shelf Pole and Shelf D7 D2D2 D2 D3D3 D3 D3 D4D4 D4 D4 D5 D5 D5 D6 D6 D6 D6 D4 D8 W1W2W1W1W2W1W3W3W4W4W3W3W3W3W3W4W4 Kitchen Hall Kitchen Hall Kitchen Kitchen HallD9Pole and Shelfexistingnew existingnew GENERAL NOTES: - The General Contractor shall be familiar with all existing conditions and shall verify all dimensions relative to the work contained herein. Any conflicts or discrepancies between depicted design and these specifications shall be reported to the owner or architect for resolution prior to the installation of work that can be changed without additional cost to owner. All assemblies and components for the project shown in the working drawings or specified to be installed complete according to normal practice and made good. All schedules shall be compared with all plans and elevations, and any discrepancies or conflicts shall be referred to the Owner or Architect prior to procurement. - All work is to be guaranteed by the contractor for one year after the final payment by the owner, or upon the date of receiving an occupancy permit. - The contractor shall take all precautions to prevent damage to existing conditions of building's exterior hardscape, plantings, interior furnishings, and finishes outside work area, during construction. - All work shall be completed in compliance with local and state plumbing, electrical, and safety codes. - All required permits are to be secured and paid for by the general contractor on a timely basis. All certificates of inspection, approvals, warranties, installation instructions and operating literature shall be turned over to the owner before final acceptance of the work. - Completion of the project shall find the premises broom clean and free of any debris. - At the job site, the permit shall be prominently displayed and Building plans shall be available at all reasonable times. FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING 1st & 2nd Floor Hall 1/8" x 12" x 12" Vinyl Tile Brosco 8385A GWB GWB Stairs / Foyer 1/8" x 12" x 12" Vinyl Tile Brosco 8385A GWB GWB Living / Dining Carpet Brosco 8385A GWB GWB Kitchen/ Hall 1/8" x 12" x 12" Vinyl Tile Brosco 8385A GWB GWB Bedroom Carpet Brosco 8385A GWB GWB Office Enttry 1/8" x 12" x 12" Vinyl Tile Brosco 8385A GWB GWB Office Bath 1/8" x 12" x 12" Vinyl Tile vBrosco 8385ABrosco 8385AGWBGWB Office Carpet Brosco 8385A GWB GWB FINISH NOTES: - 1/2" gypsum wall board fully taped and prepared for painting shall used only for partitions wholly with in each unit. - 5/8" gypsum wall board Type X both sides shall be used to separate each unit from another, from the Floor Hall, and from the Stairs. Include 3 1/2" mineral wool fire block insulation. - All closets shall have finishes equal to the rooms they serve. - Carpet by others. - Contractor shall consult owner in order to provide blocking for bathroom accessories during framing. Accessories by owner, installed by contractor. - All tub shower walls shall be protected by two piece fiberglass units decured to studs. WINDOW NOTES: - * Meets bedroom egress requirements. - Exterior Trim shall match that of the existing building. Grilles shall be as shown on exterior elevations. - Interior Trim shall be 1 x 4 #1 pine flat casings with Brosco B1268A sill (or equivalent) and 1 x 3 apron. - Double Hung Windows shall be as the units that are installed in the existing building. - All window and doors shall be installed on silicone caulking beads with 6" strips of Vycor self-adhering flashing at heads and jambs, pan flashing at all sills, and closed cell foam air sealing all rough opening gaps. WINDOW SCHEDULE MARK SIZE R.O.TYPE GLAZING W 1 2'-2 1/8 x 5'-4 7/8"Andersen WDH 2052 High performance w/simul. div. lite W 2 3'-6 1/8" x 5'-4 7/8"Andersen WDH 3452 High performance w/simul. div. lite W 3 2'-10 1/8" x 5'-4 7/8"Andersen WDH 2852 High performance w/simul. div. lite W 4 2'-10 1/8" x 4'-4 7/8"Andersen WDH 2842 High performance w/simul. div. lite W 5 2'-10 1/8" x 3'-8 7/8"Andersen WDH 2836 High performance w/simul. div. lite W 6 2'-2 1/8" x 3'-8 1/8"Andersen WDH 2036 High performance w/simul. div. lite W 7 2'-10 1/8" x 4'-8 7/8"Andersen WDH 2846 High performance w/ simul. div. lite W 8 2'-6 1/8" x 4'-0 7/8"Andersen WDH 2446 High performance w/ simul. div. lite W 9 2'-6 1/8" x 4'-0 7/8"Andersen WDH 24310 High performance w/ simul. div. lite D1 D1D1 D1 D2 D5 W5 W5 W6ss s s S CO S CO S CO S COSCO S CO DOOR SCHEDULE MARK SIZE TYPE GLAZING HARDWARE D 1 3'-0" x 6'-8" x 1 3/4"Jeldwen M-7100 N/A Entrance set, deadbolt D 2 3'-0" x 6'-8" x 1 3/4"Jeldwen Bristol N/A Entrance set, deadbolt D 3 2'-6" x 6'-8" x 1 3/8"Jeldwen Bristol N/A Passage set D 4 2'-4" x 6'-8" x 1 3/8"Jeldwen Bristol N/A Privacy set D 5 1'-4" x 6'-8" x 1 3/8"Jeldwen Bristol N/A Dummy knob w/ ball catch D 6 2 -1'-8" x 6'-8" x 1 3/8"Jeldwen Bristol N/A Louver doors w/ bipass sliding dr. set D 7 2'-6" x 6'-8" x 1 3/8"Jeldwen Bristol N/A Entrance set, deadbolt D 8 2'-8" x 6'-8" x 1 3/4"Jeldwen M-7100 N/A Entrance set, deadbolt DOOR NOTES: - Interior door shall be Jeldwen Bristol; solid, smooth finished, six panel doors. - Hardware shall be by Schlage, Plymouth series F, brushed chrome. Locks shall be keyed alike, with exterior doors mastered. - Provide clear rubber bumpers or silencer, 3 per latch side of each interior door. - Do not under cut interior doors without owners and architects approval. - Provide pan flashing at all exterior doors. - Contractor shall submit to the Architect a copy of any order for doors so that a final coordination may be made. - NA - Not applicable FIRE PROTECTION: - Install hardwired smoke and carbon monoxide detectors, as required. Installer shall meet with local fire inspector for local requirements. - = smoke detector, = combined smoke and CO detector. EXHAUST FANS: - All bathroom exhaust fans shall be hard ducted to black roof cap or white soffit cap. LIGHTING: - = Exterior wall light s S CO