Loading...
Certificate of Appropriateness for Comm ittee use only By a vote o Conditions of Approval This Certificate is hereby APPROVED Aye Nay Abstain Date New Build Addition Alteration Residential Type of Building House Garage Barn Shed Other Project Roof Windo ws/Doors Siding/Painting Solar Other Landscape Feature Fence Wall Flag Pole Pool Other New Sign Replace Sign Repaint Sign Town of Barnstable Old King's Highway Historic District Committee 367 Main Street, Hyannis, Massachusetts 02601 Telephone (508) 862-4787, Email grayce.rogers@town.barnstable.ma.us APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made, with six (6) complete, colored sets, for the issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts and Resolves of Massachusetts, 1973, for proposed work as described below and on plans, drawings, or photographs accompanying this application for: Date Date Built: Map & Parcel Property Ow ner Phone Street address Email Village Mailing address Signature Agent/Contractor Phone Agent Address Email Agent Signature If approved, the Certificate of Appropriateness expires one year from the stamped approval date or upon the expiration of a Building Permit, w hichever date shall be later. A one year ex tension may be requested, in w riting, to the Old King’s Highw ay Administrative Assistant at 367 M ain Street, Hyannis, M A 02601. This request must be received prior to the date of expiration. There is a 10 day appeal period plus a four day waiting period for all applications after w hich time your approval paperw ork w ill be availabl e for pickup and building per mit sign-off. All applications are subject to meeting any applicable building code requirements. Check all categories that apply Building Construction Commercial Sign Other _ Description of Proposed Work DENIED 301 / 0545/3/22 RICHARDS, BRUCE T & JANICE 31 SECOND WAY, BARNSTABLE, MA. 02630 Barnstable 203-561-1272 bruce.t.richards@gmail.com 31 SECOND WAY, BARNSTABLE, MA. 02630 1972 Thomas Wineman, Clean Energy Design PO Box 686, Osterville, MA 02655 508-563-6990 Info@cleanenergydesign.com Installation of roof mounted solar panel Consisting of (50) Candian Solar 400 panels - black on black CERTIFICATE OF APPROPRIATENESS – SPEC SHEET CHIMNEY Material Color ROOF Make & style Color Roof Pitch (s) – (7/12 minimum) (specify on plans for new building & major additions) GUTTER T ype/Material Color WINDOWS, DOORS, TRIM, SHUTTERS, SKYLIGHTS Window/Door Trim material Wood Other specify Size of cornerboards Size of casings (1X4 min) Color Rakes 1st member 2nd Member Depth of overhang Windows: Make/Model Material Color Window Grills Divided Light Exterior Glued Grills Grills Between Glass Removable Interior Grills No Grills Grill Pattern Doors: Style & Make Material Color Garage doors: Style Size of opening Material Color Shutters: Type & Style Material Color Skylights: Type Make & Model Material Size Color SIDING Type Clapboard Shingle Other Material Red Cedar White Cedar Other Paint Color FOUNDATION T ype (max 12’ exposed) DECK Material Color SIGNS Size Materials Color FENCE T ype (split rail, chain link) Color Material Length RETAING WALL Description LIGHTING Type and location (free standing affixed to structure, illuminated) Asph/F Gls/Cmp 4 / 12 gray/brown NEW BUILDINGS, ADDITION, OR COMMERICAL BUILDING CHECKLIST – CERTIFICATE OF APPROPRIATENESS Submit electronic complete colored set, unless otherwise noted Application for Certificate of Appropriateness Spec Sheet, brochures or diagram Site Plan Name of applicant, street location, map and parcel Name of architect, engineer, or surveyor; original stamp & signature; date of plan & revision dates North arro w, written and drawn to scale Changes to existing grades shown with one -foot contours Proposed & existing footprint of building and/or structures, and distance to lot lines Proposed driveway location Proposed limits of clearing for building (s), assessor structure (s), driveway and septic system Retaining walls or accessor y structures (e.g. pool, tennis court, cabana, barn, garage, etc) Building Elevations Plans at scale of ¼’ = 1 foot; a written drawn scale Plans at a reduced scale to fit 8.5”x11 or 11x17 paper Name of applicant, street location, map and parcel Name of Building Designer, or architect; original signature of plan preparer and stamp; plan date, and all revision dates. *All new house or comm ercial building plans must have an original signature and stamp, if any, by a registered Architect, mem ber of AIBD, or a licensed Massachusetts Hom e Improvement Contractor, unless this requirement is waived by the Old King’s Highway Historic District Committee. A written and bar drawn scale Elevations of all (affected) sides of the building, with dimensions in cluding height from the natural grade adjacent to the Building to the top of the ridge; location and elevatio n of finished grade, roof pitch (s) dormer setbacks; trim style, windo w And door styles. Changes to existing building must be clouded on drawings. Windo w schedule on plans Landscape Plan (drawn on a certified perimeter plan containing the following) Name of applicant, street address, assessor’s map and parcel number Name, address, and telephone number of the plan preparer, pl an date, & date of revisions The location of existing and proposed buildings and structures, and lot lines Natural features o f site (i.e. rock outcroppings, streams, wetlands, etc) Existing buffer areas to remain Location and species of trees and plants Driveway, parking areas, walkways, and patios, indicating materials to be used Existing stone walls, and proposed walls including retaining walls for slope retention or septic systems For removal of stone walls, you must file a demolition application All proposed exterior lighting and signs Sketch or Photos of adjacent properties A sketch (s) to scale or photographs of nearby adjacent buildings, where present, along both sides of the street frontage, Showing the proposed new house or commercial building in scale and in relationship to the existing buildings. Please discuss with staff if you do not think this is relevant to your application. Photographs of all sides of existing buildings to remain or being added to Existing building, foot print Building 1 (sq. ft.) Building 2 (sq. ft.) Exiting building, gross floor area, including area of finished basement Building 1 (sq. ft.) Building 2 (sq. ft.) New Building or addition, foot print Building 1 (sq. ft.) Building 2 (sq. ft.) New Building or addition, gross floor area, including area of finished basement Building 1 (sq. ft.) Building 2 (sq. ft.) Plan preparer, signature and date SOLAR PANEL SUPPLEMENT STRUCTURE ONE STRUCTURE TYPE Ho me Garage Barn ELEVATION PLACEM ENT North ROOF M EASUREM ENTS South East West Length SOLAR PANEL M EASUREM ENTS Height Pitch Length SOLAR PANEL TYPE & FINISH Depth Width Color Finish (matte or glossy) STRUCTURE TWO STRUCTURE TYPE Ho me Garage Barn ELEVATION PLACEM ENT North ROOF M EASUREM ENTS South East West Length SOLAR PANEL M EASUREM ENTS Height Pitch Length SOLAR PANEL TYPE & FINISH Depth Width T ype Roof Mounted Ground Mounted Canopy/Carport System Color Finish (matte or glossy) Solar Co mpany Phone Solar representative Print Name Signature Date 1.38"76.4"41.3" Black on Black Matte Clean Energy Design Thomas Wineman 5/3/22 508-563-6990 4 / 1220' 6"10' 6" Typically Dormers are about PO Box 686, Osterville, MA 02655 Tel: 508.563.6990 Fax: 888.424.8824 www.cleanenergydesign.com Site Plan Richards, 31 Second Way, Barnstable, MA 02630 Map and Parcel - 301 / 054/ Richards, 31 Second Way, Barnstable, MA 02630 PO Box 686, Osterville, MA 02655 Tel: 508.563.6990 Fax: 888.424.8824 www.cleanenergydesign.com Aerial View - with panels CS3N-380|385|390|395|400MS 380 W ~ 400 W BLACK FRAME ON BLACK BACKSHEET MONO PERC MODULE MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 400 W Module efficiency up to 19.7%400 W Better shading tolerance Minimizes micro-crack impacts MORE POWER Lower LCOE & BOS cost HiKuBlack Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa*products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. PRODUCT CERTIFICATES* MANAGEMENT SYSTEM CERTIFICATES* IEC 61215 / IEC 61730 / CE FSEC (US Florida) UL 61730 / IEC 61701 / IEC 62716 CANADIAN SOLAR (USA), INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. Canadian Solar was recognized as the No. 1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey, and is a leading PV project developer and manufacturer of solar modules, with over 55 GW deployed around the world since 2001. * For detailed information, please refer to the Installation Manual. CANADIAN SOLAR (USA), INC. 3000 Oak Road, Suite 400, Walnut Creek, CA 94597, USA | www.csisolar.com/na | service.ca @csisolar.com 1st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% 25Years Years Linear Power Performance Warranty* Industry Leading Product Warranty on Materials and Workmanship* PARTNER SECTION ENGINEERING DRAWING (mm)CS3N-400MS / I-V CURVES products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. professional skills and please carefully read the safety and installation instructions before using our PV modules. MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement 132 [2 X (11 X 6) ] Dimensions Weight Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy Cable 4 mm2 (IEC), 12 AWG (UL) Cable Length (Including Connector) 1650 mm (65.0 in) (-) / 1000 mm (39.4 in) (+)* Connector T4 series or MC4 Per Pallet 30 pieces 720 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A 12 11 10 7 6 5 4 3 2 1 0 V A 1000 W/m 2 2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 12 11 10 7 6 5 4 3 2 1 0 06 55 05 54 04 53 03 52 02 51 01 5 06 55 05 54 04 53 03 52 02 51 01 5 Rear View Mounting Hole11551300 1000 6-5Grounding Hole Mounting Hole A A B B 14Frame Cross Section A - A B - B 25 3535 35ELECTRICAL DATA | STC* CS3N 380MS 385MS 390MS 395MS 400MS 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp)36.4 V 36.6 V 36.8 V 37.0 V 37.2 V Opt. Operating Current (Imp)10.44 A 10.52 A 10.60 A 10.68 A 10.76 A Open Circuit Voltage (Voc)43.7 V 43.9 V 44.1 V 44.3 V 44.5 V Short Circuit Current (Isc)11.26 A 11.32 A 11.38 A 11.44 A 11.50 A 19.2%19.4%19.7%18.7%18.9% Operating Temperature 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 61730 1500V) or TYPE 2 (UL 61730 1000V) or CLASS C (IEC 61730) 20 A Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3N 380MS 385MS 390MS 395MS 400MS 285 W 34.1 V 8.35 A 41.3 V 9.08 A 289 W 34.3 V 8.42 A 41.5 V 9.13 A 293 W 34.5 V 8.48 A 41.7 V 9.18 A 296 W 34.7 V 8.54 A 41.9 V 9.22 A 300 W 34.9 V 8.60 A 42.1 V 9.27 A Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. CANADIAN SOLAR (USA), INC. July 2021 | All rights reserved | PV Module Datasheet v2.7J25_F30_J3_NA The high-powered smart grid-ready Enphase IQ 7A Micro™ dramatically simplifies the installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System, the IQ 7A Micro integrates with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7A Microinverter To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014, 2017 & 2020) Efficient and Reliable • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride- through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. CEC peak power tracking voltage range is 38 V to 43 V. 3. Maximum continuous input DC current is 10.2A. 4. Voltage range can be extended beyond nominal if required by the utility. 5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 11-04-2021 INPUT (DC)IQ7A-72-2-US Commonly used module pairings¹295 W–460 W + Module compatibility 60-cell, 66-cell and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range²18 V–58 V Min/Max start voltage 33 V / 58 V Max DC short circuit current (module Isc)³15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT (AC)@ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal (L-L) voltage/range4 240 V / 211–264 V 208 V / 183–229 V Maximum continuous output current 1.45 A (240 VAC)1.39 A (208 VAC) Nominal frequency 60 Hz Extended frequency range 47–68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A (L-L) branch circuit5 11 (240 VAC)11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor (adjustable)0.85 leading ... 0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0 %96.5% MECHANICAL Ambient temperature range -40ºC to +60ºC Relative humidity range 4% to 100% (condensing) Connector type: DC (IQ7A-72-2-US)MC4 Dimensions (HxWxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection — No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020, section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7A Microinverter